● ISO 9001:2015 Certified · BIS Licensed (IS 1180) · Type Tested at CPRI & ERDA · Brand Heritage Since 1970
Home / Quality & Testing
Quality engineered into every transformer — controlled at every manufacturing stage and verified by routine, type and special tests to IS, IEC and IEEE standards.
Quality Philosophy
All products of Classic Transformers are type tested and conform to I.S. specifications and IEC standards. All ratings of Classic transformers are type tested at CPRI Bengaluru, CPRI Bhopal, ERDA and ERTO Vadodara.
A strong R&D base complements our manufacturing, quality control and testing facilities, headed by highly experienced engineers and qualified personnel who ensure high quality control and attention to the details of every design. To further assure quality, and as per customer requirements, Classic Technolines regularly submits transformers for special third-party testing.
Quality Control Processes
01
Hi-B grade, laser-scribed CRGO laminations assembled on a core-forming fixture for low losses and noise.
02
Coils wound in a clean, positive-pressure environment and compressed in 100-ton pressing jigs.
03
Core-coil assemblies dried below 0.5% moisture until the required IR value is achieved.
04
ASME Section IX qualified welders; lifting lugs routinely dye-penetration tested.
05
Every tank air-pressure leak tested before painting; jointless gaskets for leak-free sealing.
06
Shot blasting to SA 2.5, zinc-rich primer and epoxy or polyurethane finish.
Transformer Testing
Routine tests, type tests and special tests are performed according to the latest IS, IEC and IEEE standards and as per customer requirements. Classification of each test follows the applicable standard and the customer specification.
Measurement of winding resistance
Voltage ratio and phase displacement check
Short-circuit impedance
Load loss, no-load loss and no-load current
Separate source high-voltage withstand
Induced over-voltage test
DC insulation resistance and PI value
Dissipation factor (tan δ) and dissolved gases in dielectric liquid
Temperature rise test
Determination of sound level
Winding hot-spot temperature rise (special)
Zero-sequence impedance (special)
Tests on on-load tap changers, where appropriate
Leakage, pressure and tightness tests
Vacuum and pressure deflection, vacuum tightness
Core and frame insulation; capacitances winding-to-earth and between windings
Special tests at NABL-accredited laboratories
Testing Equipment & Facilities
Dedicated control desks and metering for routine tests.
Qualified engineers conduct and record every test.
Core-coil assemblies inspected before tanking.
Certification & Approval References
Certifications, registrations and test laboratory references as presented in the Classic Transformers company brochure. Please confirm current certificate validity with our team for tender submissions.